PPU-231 User’s Manual

53

CITIZEN

ESC D [ n ] k NUL

[Function]

Setting Horizontal Tab Position

[Code]

<1B>H<44>H [ <n> ] k<00>H

[Range]

{0

≤ n ≤ FFH}

{0

≤ k ≤ 20H} Data is described in Hex code.

[Outline]

Specifying a horizontal tab position.

• "n" indicates the no. of columns from the beginning to the horizontal tab position. At

this time, n= set position

− 1 is to be specified. For example, to set the position at 9th

column, n=8 is to be specified.

• k denotes the number of horizontal tab positions you want to set.
• The tab position is set at position where it is "character width x n" from the line

beginning. The character width, at this time, includes the rightward space amount.
In double wide characters, it is made double of the ordinary case.

• Tab positions can be specified are maximum 32.

Specifying exceeding this is ignored.

• <n> k, which denotes a setting position, is input in the increasing order and ends at

<00> H.

• ESC D NUL clears all the set tab positions.

Following clearing, horizontal tab command is ignored.

[Caution]

When the data, <n> k, is equal to or smaller than its preceding data, <n>

k-1, it is assumed that tab setting is finished. If this is the case, the next data onward
will be processed as normal data.

When the data, <n> k, exceeds a 1-line print area, set the horizontal tab position,

assuming "Set digit position = Maximum print digits + 1." The horizontal tab
position does not change even if the character width is altered after setting the
horizontal tab position.

[Default]

• Initial value is specified for each eight characters (9

th

.17

th

.25

th

columns) of ANK

characters.

[See Also]

HT

[Sample Program]

[Print Results]

See Sample Program and Print Results for HT on Page 40.