Tycon Power RPST2424-100-280 User Manual

Page 8

Advertising
background image

8

in normal use. Note: Never store batteries for any length of time in a

discharged state or it will kill the battery.

6. SOLAR PANEL TILT: There is a solar panel tilt calculator at the

Tyconpower website

http://tyconpower.com/learning_center/

learning_center.htm

. We recommend using a fixed tilt and setting to

optimize for winter sun. The panel should face South if you are in the

Northern Hemisphere and face North if you are in the Southern Hemi-

sphere. Some typical winter tilt angles are as follows:

7. BATTERY OVERDISCHARGE: We highly recommend hooking all

equipment loads to the controller voltage output. This output will discon-

nect the load if the battery voltage drops below 11V and this will protect

the battery from over-discharge. If batteries get completely discharged

because the equipment was connected directly to the battery, you will

reduce the battery life and you will most likely need to supercharge

them with a good quality 10A automotive battery charger. Once they

are back to a normal operating range, the integrated charge controller

will maintain the charge.

8. WIND TURBINE: A wind turbine can be added to this system at any

time. Wind Turbines are good sources of power, often in times when

the sun isn’t shining, like on stormy days. We like to think of a wind tur-

bine as uptime insurance. Tycon Power Systems offers small wind tur-

bines perfectly suited to augment the RemotePro systems. The TPW-

400DT-12/24 is a 400W 12/24V wind turbine. To add a wind turbine, it

mounts to the top of a 41mm inside diameter pole. The wind turbine will

connect directly to the batteries in parallel with the solar controller.

9. POE SWITCH: Tycon Power offers a universal voltage 5 port and 8

port POE switch if more than one device needs to be powered from the

battery system. The TP-SSW5-NC, TP-SW5G-NC and TP-SW8-NC

offer the unique feature that the voltage supplied to the switch is the

POE voltage sent to the devices. So 24VDC in and you get 24VDC

POE to the devices. The operating voltage is 12V to 56VDC. The

switches mount to the DIN rail for a clean install.

Tycons TP-SW5G-24 accepts 12-36VDC input and provides four

802.3af compatible POE ports and one uplink port.

10. OTHER ACCESSORIES: Tycon also offers a variety of voltage

conversion products. Just visit

tyconpower.com

for more info.

Place

Optimum Winter Tilt

Houston / Cairo

56 deg

Albuquerque / Tokyo

60.5 deg

Denver / Madrid

65 deg

Minneapolis / Milano

69.5 deg

Winnipeg / Prague

74 deg