Vetter Pipe and Test Sealing Bags

Page 20/33

6.4 Vetter Test Sealing Bags 0.5, 1.5 and 2.5 bar

Pressure test with air

PDK 60/120 with a duct and compressed air adapter 2“ in a con-
crete pipe DN 1200 mm.

The required securing of the test bag using a
structure support has been omitted for
presentation reasons.

Description

Vetter test sealing bags 0.5, 1.5 and 2.5 bar can be used for tes-
ting, sealing and bypassing with repairs and maintenance work,
e.g. sealing tests, channel inspection, maintenance, repair and
cleaning.

9

When selecting the pipe sealing bag please observe the pres-

sure level and the counterpressure resulting from this (refer to

Technical Data).

9

0.5 bar test sealing bags RDK 140/170 and 170/200 cm can

be folded in the deflated condition so that they can then be

inserted into a standard shaft having an opening of 600 mm.

Test sealing bags can be supplied with one or two ducts for the
water test or the compressed air test. Adapters and accessories for
the water test and the com-pressed air test can also be supplied
(refer to the catalogue).

9

Connect the inflation hose(s) to the test sealing bag and the

single or double controller of the selected pressure level.

9

Position the test sealing bag, along its whole length, into the

pipeline and suitably secure it, e.g. with a structure support,

depending on the work to the carried out.

9

Inflation of the test sealing bag can be carried out according

to chapter 4.