Vetter 1.5 bar bypass bags can be used for creating a bypass with
defective channels. They can also be used for channel repairs and re-
construction as two-sided, temporary blocking with conduction and
pressure relief from the incoming pipeline to the outgoing pipeline.

9

Please observe the permitted maximum counter-pressure of 5 m

water column, resp. 0.5 bar, when using bypass bags.

9

Connect the inflation hose, 1.5 bar, to the bypass bag and the

single controller, 1.5 bar fitting.

9

Insert the bypass bag along its full length into the pipeline and

secure it against catapulting out using suitable devices, e.g. a

structure support.

9

Inflation of the bypass bag can then be made as described in

chapter 4.

Technical Data

Bypass Bags

1.5 bar / 21.75 psi

Pipe

diameter

mm /

inch

Diameter

mm /

inch

Cylinder

length

mm /

inch

Total length

mm /

inch

Air

requirement

litres /

cu. ft.

Weight,

approx.

kg /

lbs

PDK 10/20 PE core

1481004400 1 x 2 1/2“ AG

100 - 200

3.9 - 7.8

97

3.9

485

19.1

545

21.7

27

0.95

2.2

4.9

PDK 20/50 PE core

1481005000 1 x 4“ AG

200 - 500

7.8 - 20

195

7.7

550

21.7

610

24

143

5

7

15.4

PDK 50/80 PE core*

1481006900 1 x 4“ AG

500 - 800

20 - 31.5

450

17.7

565

22.2

580

22.8

310

10.9

32

70.6

PDK 50/120 PE core*

1481008000 1 x 4“ AG

500 - 1.200

20 - 47.2

450

17.7

920

36.2

935

36.8

1,420

50.1

42.5

93.7

* A 6“ or 8“ duct can be supplied when required.

Standard test counterpressure of 5 m WC / 7.25 psi.