Electrical Connection

Power supply and Controller connection

The HS-105P pan/tilt studio head uses a combined power/data floor cable (AM-SP-CAB-XXX)
that connects between the HS-105 rack mounted power supply unit (AM-PSD27-5R) and the
Power/data connector ([16], [20], [21]) on the head as shown in Fig. 8. The floor cable supplies
the HS-105P pan/tilt head with power and data communications (to/from) the Controller.

The HS-105PE environmental pan/tilt heads are supplied with an environmental floor cable
(AM-HLE-CAB-XXX) suitable for external installations.

When using the HS-105P studio pan/tilt head with the Vinten Radamec native lens drive, the
NLD adapter cable (V3980-5005) provides the connection from the supplied floor cable (AM-
SP-CAB-XXX) to the HS-105P pan/tilt head and the native lens drive. See Native Lens Drive
on page 20.

Lens drive connection

The HS-105 pan/tilt head can be used with various generic Vinten or AutoCam servo lens drives
or the Vinten Radamec native lens drive (V3977-0001).

Servo lens drives

Connect the servo lens drive to the Lens connector [17] on the HS-105PE pan/tilt head or the
NLD connector [14] on the HS-105PENLD pan/tilt head, or the Lens/Control connector [19] on