Positioning encoders – Vinten Radamec Vision 250E User Manual

Page 9

Advertising
background image

9

Positioning encoders

The Vision 250E is fitted with rotary optical incremental encoders for pan

(18)

and tilt

(20)

, ac-

cessed via a connector

(3)

on the tilt encoder. Input power to the encoders is +5 V dc at 200mA

maximum.

The quadrature square wave outputs are designed for connection to TTL-compatible circuitry and
provide high-resolution real-time digital output of up to 696,667 counts for 360° of pan and
533,333 counts for 360° of tilt.