4. Condensing Unit Installation

CAUTION:
Low ambient condition kit is required if the installation area will be below
50

°

F.

If the condensing unit is equipped with a low ambient condition kit,

do not turn on the compressor until the condensing unit has been powered
for minimum 12 hours.


1) Place the condensing units WM150~650SCU in a

properly ventilated location. If it is not, heat exhausted by
the condensing unit will build up and the cooling system
will not operate properly.

2) Condensing unit shall be elevated to avoid possible

flooding and shaded from direct sun. It shall not be
exposed to temperatures higher than 110 °F or lower than 50 °F.

3) Leave minimum 5 ft clearance for the exhaust side and leave minimum 1 foot

clearance for the ambient air intake side.

4) Service valve operations

1 - Process or Manometer
2 – Receiver Discharge or Compressor Suction
3 – Liquid Line or Suction Line
4 - Pressure Control

Back Position: Normal operation after installation is complete, process or

manometer port is closed.

Front Position: Storage or shipping operation, liquid or suction line connection

is closed.

Middle Position: Installation operation, all ports are open for evacuation, charge

and manometer.

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 10 ROTALOCK Valve Operation