Wine-Mate SSRWC Series User Manual

Page 20

Advertising
background image

- 19 -

amount of water must be provided for constant head pressure and proper
cooling, but excessive water flow will cause the unit working inefficiently.

3) The maximum permissible water pressure is 150 PSIG. If water pressure is

excessive, a pressure reducing valve must be used to reduce the water
pressure.

4) Service valve operation


1 - Process or Manometer
2 – Receiver Discharge or Compressor Suction
3 – Liquid Line or Suction Line
4 - Pressure Control

Back Position: Normal operation after installation is complete, process or

manometer port is closed.

Front Position: Storage or shipping operation, liquid or suction line connection

is closed.

Middle Position: Installation operation, all ports are open for evacuation, charge

and manometer.

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 8 ROTALOCK Valve Operation

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 9 Base Valve Operation


5.

Checking Pressure Control Settings

Suction pressure setting: Cut out=10 psig; Cut in=25 psig; Differential=15 psig

Advertising