Installation, Mounting bolt installation, Machine foundation – B&C Technologies HI Series Commercial User Manual

Page 18: Floor detail

Advertising
background image

18

Installation

HI-125

HI-85

Mounting Bolt Installation

The HI Series uses 5/8-11 x 8” bolts.
Embed the bolts in 3500 psi reinforced
concrete with a minimum of 12” thickness.
The threaded end of the bolt should extend
2 inches from the surface of the floor. As an
option, a welded bolt locating fixture is
available (rebar frame). This rigid welded
assembly is made of reinforcing rod (rebar)
and is designed to be encased in concrete.

Machine Foundation

Dynam ic Frequency

kN

lbs

kN/m 2

lbs-ft2

kN

lbs

kN/m 2

lbs-ft2

HI-85

7.56

1700

5.01

104.64

17.39

3910

11.52

240.6

HI-125

19.53

4390

10.64

222.22

25.58

5750

13.93

290.93

Hz

9.65

8

S tatic floor load

S tatic pressure

Dynam ic floor load Dynam ic pressure

6

.1

1

5

5

6

.1

1

5

5

1

5

.7

5

4

0

0

1

5

.7

5

4

0

0

4

101

4

101

15.2

386

3X

1

25

61.4

1560

5

1

.6

1

3

1

0

[email protected] (17)

Floor Detail