3

TECHNICAL DATA

(1) Reference conditions: Ambient temperature 68 °F (20 °C) - Barometric pressure 394” WC - Altitude 329 ft.
(2) Pressure at test point 8)(A)p.4, with zero pressure in the combustion chamber, with open gas ring 2)(B)p.8 at maximum burner output
(3) Sound pressure measured in manufacturer’s combustion laboratory, with burner operating on test boiler and at maximum rated output.

Burner models designation:

ACCESSORIES

(optional):

Kit for LPG operation:

The kit allows the RS 28-38-50/M burners to operate on LPG.

Modulating control kit:

Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates between the low

and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components should be ordered: •
Modulating control to install to the burner; • probe to install to the boiler.

Gas train according to UL Standards:

see page 9.

• Kit for lengthening the combustion head

L

= Standard length

L1

= Length obtainable with the kit

COD. 3010256

L = 8

1/2

L1 = 13

13/16

• RS 28/M

COD. 3010257

L = 8

1/2

L1 = 13

13/16

• RS 38/M

COD. 3010258

L = 8

1/2

L1 = 13

13/16

• RS 50/M

Model

RS 28/M

RS 38/M

RS 38/M

RS 50/M

Output

(1)

MAX.

MBtu/hr

617 - 1232

181 - 361

880 - 1665

258 - 488

880 - 1665

258 - 488

1099 - 2201

322 - 645

kW

MIN.

MBtu/hr

kW

198

58

266

78

266

78

321

94

Fuel

Natural or propane gas

- Max delivery

SCFH

1232

1665

1665

2201

- Pressure at maximum delivery

(2)

natural gas

“ WC

2.95

2.6

2.6

2.83

Operation

Low - high-low or modulating

Standard application

Boilers: water, steam, thermal oil

Ambient temperature

°F

32 - 104 (0 - 40 °C)

Combustion air temperature

°F max

140 (60 °C)

Main power supply (+/-10%)

V/Ph/Hz

120/1/60

208-230/460/575/3/60

Fan motor

rpm

W - HP

V
A

3400

370 - 0.5

120

5.2

3400

550 - 0.75

208-230/460/575

3.2 - 1.6 - 1.3

Motor capacitor

µV

45

Ignition transformer

V1 - V2

I1 - I2

120 V - 1 x 7 kV

1.6 A - 23 mA

Electrical power consumption

W max

600

750

Electrical protection

NEMA 1

Noise levels

(3)

dBA

68

70

70

72

Model

Code

Voltage

Flame safeguard

RS 28/M

C9521300

(3781070)

C9621300

(3781072)

120/1/60
120/1/60

Burner mounted

Remote panel

RS 38/M

C9522300

(3781270)

C9622300

(3781272)

C9522350

(3781470)

C9522351

(3781470)

C9622350

(3781472)

C9622351

(3781472)

120/1/60
120/1/60

208-230/460/3/60

575/3/60

208-230/460/3/60

575/3/60

Burner mounted

Remote panel

Burner mounted
Burner mounted

Remote panel
Remote panel

RS 50/M

C9523300

(3781670)

C9523301

(3781670)

C9623300

(3781672)

C9623301

(3781672)

208-230/460/3/60

575/3/60

208-230/460/3/60

575/3/60

Burner mounted

Burner mounted

Remote panel
Remote panel

Burner

RS 28/M

RS 38/M

RS 50/M

Output

MBtu/hr

358 - 1232

437 - 1665

549 - 1986

Blast tube length

inch

8

1/2

13

13/16

8

1/2

13

13/16

8

1/2

13

13/16

Code

3010270

3010271

3010272

Parameter to be checked

Probe

Modulating control

Range

Type

Code

Type

Code

Temperature

- 212...+ 932 °F (- 100...+ 500 °C)

PT 100

3010110

RWF40

3010212

Pressure

0...36.3 PSI (0...2.5 bar)

0...232 PSI (0...16 bar)

Output probe

4...20 mA

3010213
3010214

Important:

The installer is responsible for the supply and installation of any required safety device(s) not indicated in this manual.