B&C Technologies IM Series Industrial Ironer User Manual
Page 129

3
TECHNICAL DATA
(1) Reference conditions: Ambient temperature 68 °F (20 °C) - Barometric pressure 394” WC - Altitude 329 ft.
(2) Pressure at test point 8)(A)p.4, with zero pressure in the combustion chamber, with open gas ring 2)(B)p.8 at maximum burner output
(3) Sound pressure measured in manufacturer’s combustion laboratory, with burner operating on test boiler and at maximum rated output.
Burner models designation:
ACCESSORIES
(optional):
•
Kit for LPG operation:
The kit allows the RS 28-38-50/M burners to operate on LPG.
•
Modulating control kit:
Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates between the low
and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components should be ordered: •
Modulating control to install to the burner; • probe to install to the boiler.
•
Gas train according to UL Standards:
see page 9.
• Kit for lengthening the combustion head
L
= Standard length
L1
= Length obtainable with the kit
COD. 3010256
L = 8
1/2
”
L1 = 13
13/16
“
• RS 28/M
COD. 3010257
L = 8
1/2
”
L1 = 13
13/16
”
• RS 38/M
COD. 3010258
L = 8
1/2
”
L1 = 13
13/16
”
• RS 50/M
Model
RS 28/M
RS 38/M
RS 38/M
RS 50/M
Output
(1)
MAX.
MBtu/hr
617 - 1232
181 - 361
880 - 1665
258 - 488
880 - 1665
258 - 488
1099 - 2201
322 - 645
kW
MIN.
MBtu/hr
kW
198
58
266
78
266
78
321
94
Fuel
Natural or propane gas
- Max delivery
SCFH
1232
1665
1665
2201
- Pressure at maximum delivery
(2)
natural gas
“ WC
2.95
2.6
2.6
2.83
Operation
Low - high-low or modulating
Standard application
Boilers: water, steam, thermal oil
Ambient temperature
°F
32 - 104 (0 - 40 °C)
Combustion air temperature
°F max
140 (60 °C)
Main power supply (+/-10%)
V/Ph/Hz
120/1/60
208-230/460/575/3/60
Fan motor
rpm
W - HP
V
A
3400
370 - 0.5
120
5.2
3400
550 - 0.75
208-230/460/575
3.2 - 1.6 - 1.3
Motor capacitor
µV
45
Ignition transformer
V1 - V2
I1 - I2
120 V - 1 x 7 kV
1.6 A - 23 mA
Electrical power consumption
W max
600
750
Electrical protection
NEMA 1
Noise levels
(3)
dBA
68
70
70
72
Model
Code
Voltage
Flame safeguard
RS 28/M
C9521300
(3781070)
C9621300
(3781072)
120/1/60
120/1/60
Burner mounted
Remote panel
RS 38/M
C9522300
(3781270)
C9622300
(3781272)
C9522350
(3781470)
C9522351
(3781470)
C9622350
(3781472)
C9622351
(3781472)
120/1/60
120/1/60
208-230/460/3/60
575/3/60
208-230/460/3/60
575/3/60
Burner mounted
Remote panel
Burner mounted
Burner mounted
Remote panel
Remote panel
RS 50/M
C9523300
(3781670)
C9523301
(3781670)
C9623300
(3781672)
C9623301
(3781672)
208-230/460/3/60
575/3/60
208-230/460/3/60
575/3/60
Burner mounted
Burner mounted
Remote panel
Remote panel
Burner
RS 28/M
RS 38/M
RS 50/M
Output
MBtu/hr
358 - 1232
437 - 1665
549 - 1986
Blast tube length
inch
8
1/2
“
13
13/16
“
8
1/2
“
13
13/16
“
8
1/2
“
13
13/16
“
Code
3010270
3010271
3010272
Parameter to be checked
Probe
Modulating control
Range
Type
Code
Type
Code
Temperature
- 212...+ 932 °F (- 100...+ 500 °C)
PT 100
3010110
RWF40
3010212
Pressure
0...36.3 PSI (0...2.5 bar)
0...232 PSI (0...16 bar)
Output probe
4...20 mA
3010213
3010214
Important:
The installer is responsible for the supply and installation of any required safety device(s) not indicated in this manual.
119