Bradford White 65T-65FB-3X User Manual

Page 14

Advertising
background image

15

COMBINATION THERMOSTAT/GAS VALVE REPLACEMENT

Step 1. Rotate knob of the combination thermostat/gas valve

to the “OFF” position.

Step 2. Turn off gas supply to water heater.

Step 3. Disconnect gas supply line from

combination thermostat/gas valve.

Step 4. Turn off water supply and drain water heater completely.

Step 5. Remove outer jacket burner access door.

Step 6. Right side inner door removal.

a) Disconnect resettable thermal switch wire leads (leading from combination thermostat/gas valve)

and remove wire tie from feedline.

b) Remove (2) 1/4" hex drive screws from right side inner door.

c) Remove (2) 1/4" drive screws from flange section of inner door.

d) Remove right side inner door and set aside. Be careful not to damage gasket material on inner door.

Resettable Thermal Switch

Wire Connection

¼" Hex Drive Screws shown on
Right Side Inner Door.

¼" Hex Drive Screws at

Flange section of Inner Door

Remove
Wire Tie

For White Rodgers Control,
depress knob slightly and rotate
clockwise to the “OFF” position.

For Robertshaw Control, rotate
knob clockwise to the “OFF”
position.

Step 1.

Disconnect thermocouple from combination thermostat/gas valve.

Step 2.

Using a multimeter capable of measuring Ohms (or continuity),
attach one lead (alligator clip) to the pilot tube. Insert the other lead
(probe) fully into the magnet opening, Be sure the probe makes
contact only at the top center of the magnet opening. Do not allow
the probe to make contact with the threaded sides of the opening.

Step 3.

If continuity is indicated, the ECO is OK. If continuity is not indicated, the ECO has opened and the
combination thermostat/gas valve must be replaced.

ECO (Energy Cut Off) TESTING

SERVICE PROCEDURE RG-V

Combination Thermostat/Gas Valve Testing

and Replacement

Advertising