Bradford White 65T-65FB-3X User Manual

Page 6

Advertising
background image

7

Installation of Inner Door With Gasket.

WARNING

Stripped fastener connections may allow

for seal breach of inner door. A seal

breach may result in a fire or explosion

causing property damage, personal injury

or death. Do not over tighten screws in

steps 8, 10 and 11.

If a fastener connection is stripped,

contact the manufacturer listed on the

water heater rating plate.

Step 7.

Clean any residual gasket residue or other debris

from combustion chamber surface before

installing the inner door/gasket assembly.

Step 8.

Place the left side inner door into position first.
Firmly position the radiused channel of the inner
door around the feedline. Using the 1/4” hex drive
screws from step 3d, secure left side inner door in
place. DO NOT OVER TIGHTEN SCREWS.

Step 9

Position thermocouple, pilot tube and Piezo wire
against left side inner door flange gasket.
DO NOT ROUTE THROUGH RADIUSED
CHANNEL WITH FEEDLINE.

Radiused Channel

for Feedline

Position thermocouple,

pilot tube and piezo wire.

SERVICE PROCEDURE RG-I

Inner Door/Gasket Removal, Inspection

Replacement and Reinstallation

Advertising