Bradford White TW4-75S-76B-3X User Manual

Page 13

Advertising
background image

13

Venting continued-


TABLE 1 - VENT CONNECTOR LENGTHS

FOR 3 inch (7.6 cm) DIAMETER VENT PIPE

Terminating #

of

Elbows
(excl.
vent
term)

Maximum straight

Length ft (m)

Minimum

straight

Length ft (m)

48, 65 gal.

25, 55 and

75 gal.

Through the Wall

1 55

(16.8) 45 (13.7)

2 (.6)

Through the Wall

2 50

(15.2) 40

(12.2)

2 (.6)

Through the Wall

3 45 (13.7) 35 (10.7)

2 (.6)

Through the Wall

4 40

(12.2) 30 (9.1)

2 (.6)

Through the Roof

0 60

(18.3) 50 (15.2)

7 (2.1)

Through the Roof

1 55

(16.8) 45 (13.7)

7 (2.1)

Through the Roof

2 50 (15.2) 40

(12.2)

7 (2.1)

Through the Roof

3 45 (13.7) 35 (10.7)

7 (2.1)

TABLE 2 -VENT CONNECTOR LENGTHS

FOR 4 inch (10.2 cm) DIAMETER VENT PIPE

Terminating

# of 90

Elbows (excl.

vent term.)

Maximum straight

Length ft (m)

Min

straight

Length

ft (m)

48, 65 gal.

25, 55 and

75 gal.

Through the Wall

1 175 (53.3) 175 (53.3)

10 (3.1)

Through the Wall

2 170 (51.8) 170 (51.8)

10 (3.1)

Through the Wall

3 165 (50.3) 165 (50.3)

10 (3.1)

Through the Wall

4 160 (48.8) 160 (48.8)

10 (3.1)

Through the Wall

5 155 (47.2) 155 (47.2)

10 (3.1)

Through the Roof

0 180 (54.9) 180 (54.9)

15 (4.6)

Through the Roof

1 175 (53.3) 175 (53.3)

15 (4.6)

Through the Roof

2 170 (51.8) 170 (51.8)

15 (4.6)

Through the Roof

3 165 (50.3) 165 (50.3)

15 (4.6)

Through the Roof

4 160 (48.8) 160 (48.8)

15 (4.6)

NOTE: When using 4 inch (10.2 cm) vent pipe, use a 4 inch (10.1 cm) to 3
inch (7.6 cm)
reducer and exit the building wall with 3 inch (7.6 cm) vent
pipe using the 3 inch (7.6 cm)
90

vent terminal supplied. Two 45 elbows

are equivalent to one 90

elbow.





Advertising
This manual is related to the following products: