Table 3, Table 4 – Bradford White TW4-75S-76B-3X User Manual

Page 18

Advertising
background image

18

Venting continued-

TABLE 3

3 inch (7.6 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL

FOR LOW GROUND CLEARANCE INSTALLATIONS

Terminating #

of

Elbows

(excl.

vent

term.)

Max Straight

Length ft (m)

Min

straight

Length

ft (m)

48,65

gal.

25, 55

and 75

gal.

(2) 90

 Elbows with (1) 90 Elbow

1

40 (12.2) 30 (9.1)

5 (1.5)

(2) 90

 Elbows with (1) 90 Elbow

2

35 (10.7) 25 (7.6)

5 (1.5)

(2) 90

 Elbows with (1) 90 Elbow

3

30 (9.1) 20 (6.1)

5 (1.5)

(2) 90

 Elbows with (1) 90 Elbow

4

25 (7.6) 15 (4.6)

5 (1.5)

TABLE 4

4 inch (10.2 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL

FOR LOW GROUND CLEARANCE INSTALLATIONS

Terminating (Reduce 4 inch to

3 inch)

(Reduce 10.1 cm to 7.6 cm)

# of

Elbows

(excl.

vent

term.)

Max straight
Length
ft (m)

Min

straight

Length

ft (m)

48,65

gal.

25, 55

and 75

gal.

(2) 90

 Elbows with (1) 90 Elbow

1

160

(48.8)

160

(48.8)

10 (3.1)

(2) 90

 Elbows with (1) 90 Elbow

2

155

(47.2)

155

(47.2)

10 (3.1)

(2) 90

 Elbows with (1) 90 Elbow

3

150

(45.7)

150

(45.7)

10 (3.1)

(2) 90

 Elbows with (1) 90 Elbow

4

145

(44.2)

145

(44.2)

10 (3.1)

(2) 90

 Elbows with (1) 90 Elbow

5

140

(42.7)

140

(42.7)

10 (3.1)

HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,500 FEET
(762 m)
ABOVE SEA LEVEL

The capacity of the induced draft blower declines with increasing altitude due to
a reduction in the air density. In order to assure safe and reliable performance
of the water heater, contact the supplier for high altitude kit.

Advertising