Bradford White TG-199E-N User Manual

Page 37

Advertising
background image

37

Troubleshooting – Electrical

There are a number of (live) tests that are required when fault finding this product. Extreme care should
be used at all times to avoid contact with energized components inside the water heater. Only trained
and qualified service technicians should attempt to repair this product. Before checking for resistance
readings, disconnect the power source to the unit and isolate the item from the circuit (unplug it).

Table 11.

(SV1, SV2, SV3, and POV) Gas Valve and Modulating Solenoids (Set Meter Above 2k).

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

(Main) Pink-Black

11-13 VDC

36.8-44.8 ohms

H5

6-7

(SV1) Black-Yellow

11-13 VDC

36.8-44.8 ohms

H6

5-6

(SV2) Black-Blue

11-13 VDC

36.8-44.8 ohms

H7

4-6

(SV3) Black-Brown

11-13 VDC

36.8-44.8 ohms

H8

3-6

(POV) Pink-Pink

2-15 VDC

67-81 ohms

H3

9-10

Table 12.

(M) Water Flow Control Device Servo or Geared Motor.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Red-Blue

11-13 VDC

22-28 ohms

F7

9-10

Grey-Brown 4-6

VDC

n/a

F7 5-7

Grey-Yellow n/a

n/a

F7

5-8

Note: The grey wire listed above turns to black at F connector on the PCB.

Table 13.

(QS) Water Flow Sensor.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Black-Red

11-13 VDC

5.5-6.2k ohms

F2

1-3

Yellow-Black

4-7 VDC

1-1.4 Mega ohms

F2

2-3

Table 14.

By-pass Flow Control (By-pass Servo Model Only).

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Brown-White

2-6 VDC (unit

in operating

mode)

15-35 ohms

G1 1-5

Orange-White G1

2-5

Yellow-White G1

3-5

Red-White -

Ground

G1 4-5

Table 15.

(IG) Ignition System.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Grey-Grey 90-110

VAC

n/a

C1 1-2

Table 16.

(FM) Combustion Fan Motor.

Wire Color

Voltage

Resistance

Connector

No.

Pin

Nos.

Red-Black 6-45

VDC

n/a

E1 1-2

White-Black

5-10 VDC

9.2-9.4k ohms

E1

2-4

Yellow-Black

11-13 VDC

3.5-3.9k ohms

E1

2-3

Set your meter to the hertz scale. Reading across the white and black wires at terminals 2 and 4 you should read
between 60 and 420 hertz.