raised but will not hold against a sealed outlet and pump handle does not move by-pass valve is
not holding. Foreign matter in the ports is probably the trouble in all cases. Flush out by removing
valve screw, balls and filler plug and letting oil flow out valve screw hole. Replace balls and
valve screw and refill with oil.

Gauge and fittings on CAP-CHECK are sealed with Teflon pipe tape.

MODEL 5101 CAP-CHECK OUTFIT provides both the CAP-CHECK and CHASER KIT in one
compact case along with an extended base that holds the CAP-CHECK. In this way the CAP-
CHECK can be operated with one hand allowing high pressures to be easily pumped. Carrying
case has clips to hold CAP-CHECK, CHASER KIT, hose, handle, and extended base.




























IMPORTANT NOTICE -Before returning a CAP-CHECK for failure to pump MAKE SURE it
has a full charge of oil and is not air bound. Follow instructions for filling and purging air from
the pump. Over 80% of all units returned have nothing wrong with them.