General specifications, General safety precautions – Nexen EMB 130-24 964911 User Manual

Page 4

Advertising
background image

4

FORM NO. L-21081-K-0813

GENERAL SPECIFICATIONS

Size

Min Holding

Torque

Torsional Rigidity

(Estimated)

Inertia

(Calculated)

Weight

Min. Disengagement

Air Pressure

Size 2

2.25 Nm

[1.66 ft*lb]

6180 Nm/RAD

[4550 ft*lb/RAD]

0.00002 kg*m^2

[0.0005 lb*ft^2]

1.1 kg

[2.4 lbs]

5.5 bar

[80 psi]

Size 3

8 Nm

[5.90 ft*lb]

9613 Nm/RAD

[7090 ft*lb/RAD]

0.00005 kg*m^2

[0.0012 lb*ft^2]

1.5 kg

[3.2 lbs]

5.5 bar

[80 psi]

Size 4

22 Nm

[16.2 ft*lb]

23,796 Nm/RAD

[17,550 ft*lb/RAD]

0.00031 kg*m^2

[0.0074 lb*ft^2]

3 kg

[8.5 lbs]

5.5 bar

[80 psi]

Size 5

45 Nm

[33 ft*lb]

36,184 Nm/RAD

[26,690 ft*lb/RAD]

0.00114 kg*m^2

[0.0271 lb*ft^2]

6.3 kg

[13.8 lbs]

5.5 bar

[80 psi]

IEC 71

14 Nm

[10.3 ft*lb]

8120 Nm/RAD

[5990 ft*lb/RAD]

0.00031kg*m^2

[0.0074 lb*ft^2]

10 kg

[22 lbs]

3.3 bar

[48 psi]

IEC 80

45 Nm

[33 ft*lb]

13,450 Nm/RAD

[9,920 ft*lb/RAD]

0.0014 kg*m^2

[0.033 lb*ft^2]

15 kg

[33 lbs]

5.5 bar

[80 psi]

IEC 90

45 Nm

[33 ft*lb]

29,560 Nm/RAD

[21,800 ft*lb/RAD]

0.0014 kg*m^2

[0.033 lb*ft^2]

15 kg

[33 lbs]

5.5 bar

[80 psi]

EMB 625

45 Nm

[33 ft*lb]

5,430 Nm/RAD

[4000 ft*lb/RAD]

0.0014 kg*m^2

[0.033 lb*ft^2]

12.5 kg
[27 lbs]

3.3 bar

[48 psi]

EMB 875

45 Nm

[33 ft*lb]

20,470 Nm/RAD

[15,100 ft*lb/RAD]

0.0014 kg*m^2

[0.033 lb*ft^2]

12.5 kg
[27 lbs]

3.3 bar

[48 psi]

GENERAL SAFETY PRECAUTIONS

CAUTION

WARNING

CAUTION

Some product assemblies can exceed

30 lbs. Use lifting aids and proper lifting

techniques when installing, removing, or

placing in service.

CAUTION

Watch for sharp features when

interacting with this product. The parts

have complex shapes and machined

edges.

This product is capable of emitting

a spark if misused, therefore it is not

recommended for use in any explosive

environment.

The output shaft needs to be enclosed

either by gear reducer or appropriate

guarding. Failure to guard could result

in serious bodily injury.

Pneumatic units accept an optional solenoid valve (normally closed) controlled by 24VDC at 104 mA. Solenoid valves are
fitted with 18" flying leads standard. To order the solenoid valve (optional), please refer to Nexen product #964650.

CAUTION

The output shaft needs to be enclosed

either by gear reducer or appropriate

guarding. Failure to guard could result

in serious bodily injury.

CAUTION

The temperature limits for the

product are 4.5-100 degree

Celsius (40-220 degree F).

Advertising