FORM NO. L-21081-L-0813

BRAKE ASSEMBLY

OPERATION

WARNING

Never exceed maximum operating speeds

listed for your product. (See Table 4).

CAUTION

CAUTION

TABLE 4

The temperature limits for this product

line are 4.5-100 Degree Celsius (40-

220 Degree F).

Never exceed life of facing material. Facing

life depends on the volume of material and

the total energy over the life of the unit.

Expected life (in hrs) can be found by:

Time=Volume/(Power*Wear Rate).

Sizes

Max RPM

Size 2, 3, 4, 5

10,000

IEC 71, 80, 90

10,000

EMB 625, 875

5,000

FIGURE 6

* Note: This is a single row bearing in EMB 625,

EMB 875, and Servo Size 5.

Friction Facing

Air Chamber

Piston

O-Ring Seals

Bearing*

Output Shaft

Air Chamber

Air to Brake

Wave Spring

Clamping Collar

Input Flange

Quick Exhaust Valve

and/or

Optional Solenoid Valve

(as shown)

Advertising