FORM NO. L-20008-V-0511

Refer to Figures 15-18.

1. Loosen the Set Screws (Item 16) and remove the

Locking Collar (Item 19).

2. Remove the Retaining Ring (Item 11).

3. Remove the Spacer (Item 18).

4. Press the Drive Flange (Item 15) and Hub (Item 1) off

the Cylinder (Item 2) and Drive Ring (Item 4).

5. Remove the old Compression Springs (Item 7).

NOTE: At this point, the spline on the Hub (Item 1) can

be lubricated, with Never-Seez® without further
disassembly.

6. Separate the Piston (Item 3) from the Cylinder (Item

2)

7. Remove and discard the old O-Ring Seals (Items 12

and 13).

8. Remove the Retaining Ring (Item 10).

9. Press the old Ball Bearing (Item 8) and Drive Ring (Item

4) out of the Cylinder (Item 2).

10. Press the old Ball Bearing (Item 9) out of the Piston

(Item 3).

11. Using a bearing puller, remove the Drive Ring (Item 4)

from the Ball Bearing (Item 8).

12. Clean the bearing bore of the Cylinder (Item 2) and

Piston (Item 3) with fresh safety solvent, making sure
all old Loctite® residue is removed.

13. Apply an adequate amount of Loctite® 680 to evenly

coat the outer races of the new Ball Bearings (Items 8
and 9); then, press the new Ball Bearing (Item 8) into
the Cylinder (Item 2) and the new Ball Bearing (Item
9) into the Piston (Item 3).

14. Reinstall the Retaining Ring (Item 10).

15. Apply a thin coat of O-Ring lubricant to the O-Ring

contact surfaces of the Piston (Item 3), Cylinder (Item
2), and the new O-Ring Seals (Items 12 and 13).

PARTS REPLACEMENT - 5H100P

CAUTION

Working with spring loaded or tension
loaded fasteners and devices can cause
injury. Wear safety glasses and take the
appropriate safety precautions.

FIGURE 15

1

4

16

15

11

18

19

7

2

FIGURE 16

8

4

3

2

12

13

9

10

Do not

remove

Backing Plate

(Item 6).

FIGURE 17

18

16

9

15

11

1

19

10

Advertising