AlphaServer 800 Pedestal–Rackmount

Alpha Servers 2.45

Uninterruptable Power Supplies

Prestige 1250EXT

UPS offerings include EIA232 port for local or network monitoring and plug-in battery extension provisions to increase run
time up to two hours. For complete protection, UPS products should be used with data line surge protectors and UPS
monitoring software.

Solutions for Pedestal Systems

4N-AEABF-AA

Prestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 120V 6-foot cord with 5-15P plug, (4) 5-15R
receptacle, 9 minutes battery at full UPS load.

4N-AEABF-BF

Prestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 200-240V in/out selectable. Uses system
power cord for detachable IEC320 input connection at UPS. Includes (3) IEC320 10A output
receptacles, (2) output jumpers with IEC320 connectors to system.

4N-AEABF-BB

Extension pack for 120V 60 Hz models, up to four packs at 30 minutes per pack supported

4N-AEABF-BD

Extension pack for 240V 50 Hz models, up to four packs at 30 minutes per pack supported

4N-AEAEO-PA

Hot-swap Power-Pass Module for 60 Hz UPS with (7) 5-15R Surge Protected outlets.

4N-AEAEO-PB

Hot-swap Power-Pass Module for 50 Hz UPS with (6) IEC320, 10A surge protected outlets.

4N-AEWAR-G1

Prestige 5 year on-site exchange warranty upgrade (US only).

Rackmount UPS

UPS Model

Application

Type

Receptacle module

4N-AEAAH-FA 60Hz

Rackmount UPS, supports up to 5 systems 3kVA Custom RM

1

Included

2

4N-AEAAH-FB 50Hz

Rackmount UPS, supports up to 5 systems 3kVA Custom RM

1

Included

4N-AEAAJ-CL

3

60Hz

Out of Cabinet UPS

6kVA Prestige

4

Included

4N-AEAAJ-CU 50Hz

Out of Cabinet UPS

6kVA Prestige

4

Hardwired

1. Factory installation must be specified at time of order. Up to two UPS systems, one UPS for up to 5 fully configured

systems. Recommended UPS distribution option combines multiple UPS input plugs into a single L6-30P plug-in
connection to simplify future UPS add-on. Order 4NAEAAH-FF 60 Hz; 4N-AEAAH-FG 50 Hz).

2. Includes six IEC receptacle strips for connection to IEC plugs in cabinet.
3. 208-120/208V shown; order 4N-AEAAJ-CT for 240-120/240V models
4. Optional mobile stacker with seismic mounting provision for 6kVA Prestige (4N-AEACH-HD)

4N-AEAAJ-CL

Prestige 6 kVA (4 kW), single phase, 60Hz, 208-120/208V, 6 ft. cord with L6-30P and (2) L6-30R,
(8) 5-15R receptacle. Modular hot-swap design with 7 minute battery at full UPS load, extendible
plug and play batteries and receptacle provisions. Substitute -CT for 240V 240/120V operation.

4N-AEAAJ-CU

Prestige 6 kVA (4 kW) 50Hz package, single phase, 50Hz, 200-240V in/out selectable, hardwired
input/output.

4N-AEWAR-G3/G4

Prestige 5 year on-site exchange warranty upgrade for 4N-AEAAH-CM/CT. G4 provides on-site
remedial and start-up service.

UPS Monitoring and Unattended Shutdown Software (for above UPS systems only) is included in ServerWORKS Kits
shipping with all AlphaServers. Order Cable Kit separately.

4N-ONLIN-NT

Cable Kit for DIGITAL UNIX

4N-ONLIS-FE

Cable Kit for OpenVMS

Network Management or multi system shutdown (via SNMP or ServerWORKS Manager) for DIGITAL UNIX and
OpenVMS requires Network Adapter option.

60 Hz Applications

50 Hz Application

Network Adapter Option

4N-AEAEO-DB/DD

4N-AEAEO-DB/DD

Prestige 3 kVA RM, DB=Twisted pair; DD=ThinWire

4N-AEAEO-DA/DC

4N-AEAEO-DB/DD

Prestige 6 kVA and PUPS Plus UPS, DA/DB=Twisted pair; DC=ThinWire

Note: Multiple system shutdown via OpenVMS requires multi-port hardware option (RN-JMIU4-AB). Ports can be daisy

chained.