Installation – Outdoor Great Room Santa Fe 36 User Manual

Page 4

Advertising
background image

Do not locate appliance where it can get excessively wet. Do not use this appliance if any part has been
underwater. Immediately call a qualified service technician to inspect the unit and to replace any part of the
control system and any gas control which has been underwater.

Installation and repair should be done by a qualified service person. The appliance should be inspected
before use and at least annually by a qualified service person. More frequent cleaning may be required as
necessary. It is imperative the control compartment, burner and circulation air passageways of the
appliance be kept clean and free.

If it is evident there is excessive abrasion or wear of any of the components, if the fuel supply hose is cut
or cracked, it must be replaced prior to the appliance being put into operation.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away
to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the area of the appliance.

Clothing or other flammable materials should not be hung from the appliance, or placed on or near the
appliance.

Any guard or other protective device removed for servicing the appliance must be replaced prior to
operating the appliance.

Inspect the fuel supply connection for signs of leakage (including the hose for LP models) before each
use of the appliance.

The pressure regulator and hose assembly supplied with LP models must be used. Replacement
pressure regulator and hose assemblies must be those specified in this manual.

The 20lb LP gas supply cylinder used with LP models must be constructed and marked in accordance
with the specifications for LP-gas cylinders as required by the U.S. Department of Transportation (DOT)
or the Canadian Transport Commission (CTC).

The 20lb LP gas cylinder supply system must be arranged for vapor withdrawals.

The 20lb LP gas cylinder used must include a collar to protect the cylinder valve.

When an LP model is not in use, the LP-gas must be turned off at the 20lb supply cylinder.

To extend the life of your TRIPARO Gas Log Fire Pit, protect and cover it from the elements when not in
use. Ensure fire pit has ample time to cool off after use and prior to installing storage cover. Damage
caused to storage cover due to heat or burns are not covered by warranty.

INPUT

Model

Fuel

Max. Input

Btu/Hr

Celtic / Milan

10” Ring

Natural Gas

77,000

Celtic / Milan

10” Ring

Propane

56,000

Heritage 12”

Natural Gas

65,000

Heritage 12”

Propane

65,000

MonteCarlo 12”

Natural Gas

71,000

MonteCarlo 12”

Propane

77,000

Maximum Inlet Gas Supply Pressure

Natural

Gas

LP(Propane)

Intended Operating

Pressure

7.0” w.c.

11.0”w.c.

MINIMUM CLEARANCE TO COMBUSTIBLES

Inches

mm

Floor

0

0

Side Walls

48

1,219

Top of unit to ceiling

72

1830

NOTE – LP refers to Liquid Propane Fuel Type
NOTE – w.c. refers to Water Column

INSTALLATION

Advertising