Pet fountain reassembly, En es fr it nl de – Petsafe Drinkwell® Ceramic Avalon Pet Fountain User Manual

Page 12

Advertising
background image

www.petsafe.net

13

12

www.petsafe.net

EN

ES

FR

IT

NL

DE

4. Once the Stator is removed, remove the Impeller

(3-bladed propeller). The Impeller is held in
place by a magnet, simply insert a fingernail or
other slim object underneath the plastic blade
and lift out (

fig. 14).

5. Once the Pump is completely disassembled, you

can clean the parts with soap and warm water.
Use a cotton swab or the “motor” brush from the
Drinkwell

®

Cleaning Kit to clean inside the Pump’s

motor cavity and remove any build up (

fig. 15).

For added disinfecting and/or hard water
removal, clean the Pump with white vinegar.

6. Once the parts are clean and well rinsed, you

can reassemble the Pump for use.

a) Replace the Impeller.

b) Replace the Stator.

c) Replace the Faceplate.

pet fountain reassembly

1. Place the Pump inside the Foam Filter (

fig. 16)

then place inside the square indention in the
Bowl. Make sure the circular opening, Pump
outflow on top of the Pump, is positioned in the
bottom right corner (

fig. 17).

2. Press down on the Pump to engage the suction

cups. Once the Pump is securely in place, feed
the Inline Plug of the electrical power cord over
and through the raised post and out the notch
on the bottom side of the Bowl (

fig. 18).

3. Remove the extra slack from the electrical power

cord and insert the Rubber Cap into the raised
post. Make sure the cord channel on the Rubber
Cap is aligned with the electrical power cord,
then insert your finger into the Rubber Cap and
push all the way down (

fig. 19).

4. Fold the top of the Rubber Cap over the raised

post to seal off the Bowl.

5. Rinse a new Charcoal Filter thoroughly in cold

water to help remove any excess and loose
charcoal dust.

fig. 14

fig. 15

Electrical

power

cord rests

on top

fig. 16

fig. 18

Pump

Outflow

fig. 17

Advertising