Operation – Ryobi P730 User Manual

Page 14

Advertising
background image

14

OPERATiON

QUiCk SHUTOff SWiTCH

See Figure 15.
Depress the quick shutoff switch at any time to stop the
inflator.

DiGiTAL GAUGE

See Figures 15.

NOTE: Digital gauge displays pressure of high
pressure hose only. Preset features apply to high pressure
applications only.
The digital gauge on the inflator is multifunctional. It serves
as a pressure gauge, monitors the amount of pressure being
applied to the item being inflated, and can change air pres-
sure measurement units from PSI to BAR to KG/CM



.

To turn the digital gauge ON, press the ON/RESET button
or depress the switch trigger.
NOTE: Make sure digital gauge is set at 0 before use. If gauge
reads “Err” or needs resetting, press and hold

ON/RESET

button for 4-7 seconds.
NOTE: The digital gauge will automatically shut off when not
in use for  and a half minutes or more.
To use the pressure gauge feature:

Turn digital gauge on by pressing

ON/RESET button or

depressing and releasing switch trigger.

Place air chuck over valve stem and lock in place. Readout

will appear on gauge.

NOTE: The pressure readout on the gauge while inflating
is a measurement of the fluctuating pressure between the
item and the high pressure hose. To get an accurate read-
ing, stop inflating and follow above instructions for reading
the air pressure.

To switch from PSi, kG/CM

2

, and BAR:

With gauge

ON, press and hold down ON/RESET button

for a

t least 7 seconds.

The current measuring unit will flash. Press the

ON/RESET button again to select the desired measur-
ing unit.

The setting takes effect after the display stops flashing.

(4-7 seconds)

NOTE: After preset pressure has been set, pressure setting
stays in the gauge memory for 10 seconds. To recall the
previous pressure setting for up to 10 seconds after infla-
tion, press the (

+ ) or ( - ) button.

To reset preset pressure, press and hold the

ON/RESET

button.

iNfLATiNG MANUALLY fOR HiGH AND LOW
PRESSURE APPLiCATiONS

Connect either high

or low pressure hose to item to be

inflated.

Depress and hold switch trigger until desired pressure is

reached.

Release the switch trigger.

PRESSURE

GAUGE

(+)

BUTTON

(-)

BUTTON

ON/RESET

BUTTON

Fig. 15

AIR PRESSURE

QUICK

SHUTOFF

SWITCH

iNfLATiNG USiNG THE PRESET PRESSURES
fEATURE WiTH AUTOMATiC SHUTOff

NOTE: Digital gauge displays pressure of high pressure
hose only.

With gauge

ON, press and hold down ( + ) or ( - ) buttons

to select desired shutoff pressure.

NOTE: Numbers will flash while setting pressure. Holding
buttons down will make the pressure number increase/
decrease faster.

Depress switch trigger.

Push the lock-on button forward.

Release the switch trigger and the inflator will continue

running.

NOTE: For preset pressures of 39 PSI, .68 BAR, or .74
KG/CM



or less, the unit will automatically stop just short

of the preset pressure. Manually depress the switch trigger
again to release the lock-on button and provide an additional
short “burst” of air to achieve preset pressure.
For preset pressures of 40 PSI, .75 BAR, or .74 KG/
CM, or greater, the unit will automatically stop at 40 PSI,
.75 BAR, or .74 KG/CM regardless of preset pressure
setting. This feature helps guard against over inflation and
possible bursting. Manually depress the switch trigger again to
release the lock-on button and continue inflating by hold-
ing the trigger in the

ON position to achieve desired pres-

sure. Shutoff will occur again just before target pressure is
reached.
NOTE: Read actual pressure only when unit is not
operating.

Advertising