ASSEMBLY

REMOVING / REPLACING THE THROAT PLATE

See Figure 17.

WARNING:

The throat plate must be below the saw table. If the throat
plate is too high or too low, the workpiece can catch on
the uneven edges resulting in binding which could result
in serious personal injury.

Never operate the saw without a throat plate installed.
To remove / replace:

Unplug the saw.

Remove the screws securing the right side of the zero

clearance throat plate.

Lift the throat plate from the saw. Repeat the above steps

for the left side of the throat plate.

To reinstall the throat plate, align the holes in the throat

plate with the holes in the saw base.

Retighten the screws, being careful not to overtighten

which can cause the throat plate to bow or bend.

ADJUSTING SUPPORT FOOT

See Figure 17.
When making sliding cuts, turn the support foot clockwise
or counterclockwise depending on the amount of support
needed.

THROAT

PLATE

Fig. 17

SUPPORT

FOOT