MAINTENANCE INSTRUCTIONS

Valve will not flow water

Valve leaks when shut-off.

Replace Hot and Cold washers and
inspect top surface on hot and cold

seats for damage.

Pressure balancing piston housed in
control spindle assembly is blocked

from free movement by foreign

matter.

With valve open half way, remove
temperature handle and tap

spindle with plastic hammer. If
problem is not solved, remove
spindle assembly completely and

tap handle end against a solid object
to free piston. Rinse out control

sample assembly. Soaking in house-
hold vinegar will help free foreign
matter build-up.

Hot and cold water not turned on.

service stops not opened.

Be sure both supplies are turned on

and service stops are opened.
Valve will not operate unless both

HOT and COLD water inlets have
pressure.

Hot and cold water washers are

worn, or foreign matter (solder,

chips, etc.) are between washers
and seat surfaces.

Water volume from valve is

inconsistent during operation.

Valve delivers an insufficient quantity

of Hot and Cold water.

Temperature fluctuates without

moving temperature handle.

Temperature out of valve reduces
gradually during use.

Supply system is running out of hot

water.

Reduce maximum flow rate out of

valve or shower head. This will allow

longer period of use before
reduction of hot water supply.

While using a tub & shower valve
with integral diverter set for shower,

a trickle of water runs from tub
spout.

This is a design function of the valve.
Water is allowed to trickle from the
tub spout when diverter is set in

shower position; in accordance to
national standards.

PROBLEM

CAUSE

SOLUTION

This is a design function in accordance
to national standards.