Matrix Switching System—User Manual

39

LB (Length) :

LB value is always 2 (Data1 + Data2). Not include the CRC byte.

Data : Response the data refer to the table

F/W Version :

Contains the VerA, VerB and VerC (ex: VerA.VerB.VerC)

Data1 : Bit 7~4 : VerA (Range 0 - 9)

Bit 3~0 : VerB (Range 0 - 9)

Data2 : Bit 7~0 : VerC (Range 0 - 99)

If the Data1 is 0x10 and Data2 is 0x07

=> VerA = 1, VerB = 0 and VerC = 7, Firmware version is v1.0.07

If the Data1 = 0x23 and Data2 = 0x45

=> VerA = 2, VerB = 3 and VerC = 69, Firmware version is v2.3.6

Request

0x07

0x08

0x09

0x0A

0x0B

0x0C

0x11

0x13

0x15

0x17

0x19

0x21

Request Description

Index

Value

Request Status of Video Output

Output

Input

Request Status of Audio Output

Request Video Input Plug Status

Input

1: Plug
0: Unplug

Request Audio Input Plug Status

Request Video Output Plug Status

Output

Request Audio Output Plug Status

Request Audio Mute Status

Output

0: Unmute, 1: Mute

Request Audio Volume Level

Level Range

(0 - 100)

Request Audio Bass Level

Request Audio Subwoofer Level

Request Audio Treble Level

Request EDID Type

Input

0: Default, 1: Output 1

Type C ACK + LB + Data1 + Data2 + CRC (Total 5 Bytes)

Name

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

ACK

ACC

0

0

LB

Data1

Data2

CRC

Device ID (0 - 31)

Length

Data 1

Data 2

CRC

Request

0x31

VerA

VerB

Request Description

Data1

Data2

Request Firmware Version

VerC