Wilbur Curtis WB-10-60 User Manual

Service manual – wb-10 water boiler

Advertising
background image

MODELS INCLUDED

WB-10-12

WB-10-60

C

CAUTION: Please

use this setup

procedure before

attempting to use this

appliance. Failure to follow

the instructions can result in

injury or the voiding of the

warranty.

WARNING HOT

LIQUID, Scalding

may occur. Avoid

splashing.

WARNING: DO NOT

place this water

boiler closer than

six [6] inches from

wall. Unit must have adequate

cross-ventilation.

CAUTION: DO NOT

connect this unit

to hot water. The

inlet valve is not rated for hot

water.

FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM

Important Safeguards/Symbols

Service Manual – WB-10 Water Boiler

W

ilbur

C

urtis

C

ompany

, i

nC

.

Symbols:

WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements

This equipment is designed for commercial use. Any servicing other

than cleaning and routine maintenance should be performed by an

authorized Wilbur Curtis Company service technician.

• DO NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, DO NOT open service

panels. There are no user serviceable parts inside.

• Keep hands and other items away from hot areas of the unit dur-

ing operation.

• Never clean with scouring powders or harsh chemicals.

INSTALLATION

This Curtis unit is pre-set and ready to go from the factory.
System Requirements:

• Water Supply 20 – 90 PSI (MINIMUM FLOW RATE of 2 GPM)*

• Electrical: See electrical schematic.

Factory Settings:

• Water Temperature 200ºF

• Volume 10 Gallons

NOTE: A water filtration system must be used to help maintain trouble-free operation. In areas

with extremely hard water, we highly recommend the use of a Curtis approved water filter. (For

our full line of filters, please log on to www.wilburcurtis.com) A water filtration system will greatly

prolong the life of the unit and enhance the quality and taste of the product.

SETUP STEPS

1. The unit should be level (left to right - front to back), on a secure surface.
2. Install the supplied water faucet on the faucet shank in front of the unit.

NSF requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required

so that the unit can be moved for cleaning.

2. This unit must be installed with adequate backflow protection to comply with applicable

federal, state and local codes.

3. Water pipe connections and fixtures directly connected to a portable water supply shall be

sized, installed and maintained in accordance with federal, state, and local codes.

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO.

6913 Acco Street,

Montebello, CA 90640-5403

For the latest information go to

www.wilburcurtis.com

Tel: 800/421-6150

Fax: 323/837-2410

Advertising
This manual is related to the following products: