5 advanced features and options – Crown CTS 4200 User Manual

Page 15

Advertising
background image

page 15

CTs Multi-Channel Power Amplifiers

Operation Manual

5.2.4 Channel Level Control

The signal level for each input can be attenu-
ated accurately by adjusting the 21-step Level
Control (see Section 4.2). Figure 5.2 shows the
amount of attenuation in dB for each detent.

Note: Attenuation per detent varies with operat-
ing mode since gain varies with operating
mode. Attenuation amounts shown may vary
±6%.

Detent

4/8 Ohm

70V

100V

0 (full CCW)

-68.31

-72.90

-71.02

1

-67.54

-72.06

-70.26

2

-32.23

-36.61

-34.90

3

-25.46

-29.74

-28.00

4

-21.83

-25.87

-24.22

5

-19.23

-23.20

-21.58

6

-17.12

-20.94

-19.40

7

-15.36

-19.02

-17.53

8

-13.76

-17.22

-15.79

9

-12.28

-15.53

-14.20

10

-10.84

-13.90

-12.62

11

-9.51

-12.32

-11.16

12

-8.28

-10.87

-9.81

13

-7.09

-9.45

-8.45

14

-6.30

-8.11

-7.22

15

-4.92

-6.70

-5.94

16

-3.82

-5.26

-4.63

17

-2.62

-3.70

-3.21

18

-1.35

-1.90

-1.66

19

-0.01

-0.01

-0.01

20 (full CW)

0.00

0.00

0.00

ATTENUATION in dB

Figure 5.2 Level-control Attenuation per Detent