6 troubleshooting – Crown CTS 4200 User Manual

Page 18

Advertising
background image

Operation Manual

CTs Multi-Channel Power Amplifiers

page 18

CONDITION: No sound, even though
the amp has power.
Power LED is on
without flashing and the amp is receiving an
input signal. Signal indicator is flashing.

•

Speakers not connected.

•

Open circuit due to speaker failure.

CONDITION: No input signal.
(Signal indicator is not flashing even though
audio is applied and channel is ready).

POSSIBLE REASON:

•

Input signal level is very low.

•

Input cables have become disconnected.

•

There is a short on the amplifier

output. First disconnect your speakers
from the affected channel(s) one by one
to determine if one of the loads is
shorted.

6 Troubleshooting

CONDITION: Thermal indicator is
flashing.

POSSIBLE REASON:

•

The amplifier has become too hot for

safe operation. Check for loads less than
2 ohms, and for excessive input levels.
Check for proper ventilation and proper
mode-switch setting. Driving low-
impedance loads while in high-voltage
mode can cause overheating.

CONDITION: All channel thermal
indicators are flashing.

POSSIBLE REASON:

•

Power supply thermal overload.

•

DC or excessive low-frequency signal at

the amplifier’s output has enabled
speaker protection.

CONDITION: Bridge LED is flashing.

POSSIBLE REASON:

•

The mode switch was switched while the

power was on.