Manual-16 – Rane SR 2 User Manual
Page 16

Manual-16
Cable Type 2
4 twisted pair unshielded CAT 5, Belden #1583(A, B, E, ENH, R)
4 twisted pair shielded CAT 5, Belden #1624 (P, R)
4 twisted pair unsheilded CAT 5, Belden #1700 (A, R)
Note: This table is only for systems using SR 2 remotes (all remotes on 485 bus are
the same). For mix and match calculation of SR 2, SR 3 and SR 4 Remotes, use the
SRCABLELENGTH.XLS Microsoft Excel™ spreadsheet on the Drag Net CD-ROM or
at www.rane.com/sr2.html.
Requires
external
supply
Max Distance
for Cable (feet)
Max Distance for
Cable (meters)
Number of
SR 2 Remotes
Vs = 15V
RPM 44
RPM 22
1000
305
1
1000
305
2
1000
305
3
1000
305
4
1000
305
5
1000
305
6
1000
305
7
1000
305
8
Vs = 12V
RPM 88
1000
305
1
1000
305
2
1000
305
3
1000
305
4
1000
305
5
946
288
6
822
251
7
727
222
8
Vs = 8V
769
235
1
477
145
2
345
105
3
271
83
4
223
68
5
189
58
6
164
50
7
145
44
8