Manual-26 – Rane SR 2 User Manual
Page 26
Advertising

Manual-26
IF
Input Force
Forces new main level and second level. Resets the command state to No Operation.
The main level is updated and indicated by the LED regardless of Auto Level configu-
ration.
If Auto Second Level is enabled, the second level is updated and indicated by the
flashing LED. Otherwise, if Auto Second Level is disabled, the second level is up-
dated.
Send: IF,n1,n2
Where: n1 is the new main level. The main level range is [0, 31].
If n1 is zero, the main level remains unchanged.
n2 is the new second level. The second level range
is [0, 31]. If n2 is zero, the second level remains
unchanged.
Example: IF,3,5 sets a new main level of 3 and a new second level
of
5.
Response: "OK"