Dutchwest non-catalytic convection heater, Wall pass-throughs, Hearths – Vermont Casting Non-Catalytic Convection Heater 2477CE User Manual

Page 8

Advertising
background image

8

Dutchwest Non-Catalytic Convection Heater

30003849

ST797

thru fireplace

5/04

Flue Liner

Extend Chimney Con-

nector to the First Tile of

the Flue Liner

Observe

Miniumum Clearances

Damper

Plate is

Removed

or Locked

in Open

Position

Close Off

the Damper

Opening with

Sheet Metal

and Sealant

ST797

Fig. 8 The connector passes through the fireplace to enter
flue. Special Fireplace Adapter Kits to simplify fireplace instal-
lations are available from your local dealer.

ST421

hollow wall pass through

6/2/04 djt

457 mm (18”) Empty

Space All Around the

Chimney Connector

Sheet Metal

Cover

(One side

only)

ST421

Fig. 9 Hollow wall pass-through.

Wall Pass-Throughs

Whenever possible, design your installation so the con-
nector does not pass through a combustible wall. If you
must use a wall pass-through in your installation, check
with your building inspector before you begin and con-
struct it in accordance with local building codes. Also
check with the chimney connector manufacturer for any
specific requirements.
Accessories are available for use as wall pass-
throughs. If using one of these, make sure it has been
tested and listed for use as a wall pass-through.
Figure 9 shows one method, in which all combustible
material in the wall is cut away to provide the required
457 mm (18”) clearance for the connector. The resulting
space must remain empty.
A flush-mounted sheet metal cover may be used on one
side only. If covers must be used on both sides, each
cover must be mounted on non-combustible spacers
at least 25 mm (1”) clear of the wall. Your Dutchwest

Hearths

This appliance must be installed on to hearth that
meets the requirements of Part J of the Building Regu-
lations 2000 (Combustion Appliances and Fuel Storage
Systems). This can be achieved by ensuring that the
hearth is constructed and sized in accordance with the
guidelines included in section 2 of approved document
‘J’. The size and clearances of the hearth are as fol-
lows:

The constructed hearth should be constructed in ac-
cordance with the recommendations in document J,
and should be of minimum width 840 mm and minimum
depth 840 mm (if a free standing hearth b) above) or
a minimum projection of 150 mm from the jamb (if a
recessed hearth a) above).

Costructional Hearth

Dimensions as below

At least
300 mm

At least 150 mm

or to a suitable

heat resistant wall

At least

150 mm

Hearth Surface

Free of Com-

bustible Material

Perimeter should be

clearly marked e.g.

edge of superimposed

hearth

Perimeter should be

clearly marked e.g.

edge of superimposed

hearth

Appliance

Doors

Appliance

Doors

ST912

Fig. 10 Noncombustible hearth surface dimensions.

a) Fireplace recess

b) Free standing

dealer or your local building inspector can provide de-
tails of other approved methods of passing a chimney
connector through a combustible wall.
DO NOT CONNECT THE HEATER TO ANY AIR DIS-
TRIBUTION DUCT OR SYSTEM.

Advertising