Beckett 7600 AquaSmart Boiler Control User Manual

Page 16

Advertising
background image

16

Figure 14 - 7600A/B alternate multi-zone connections

with or without a tankless coil

Water Flow:

Control Wiring (Option 1): 7600B only

CAUTION - Always observe proper polarity when connecting multiple transformers in a

system (connect red terminal of external transformer to TR terminal of AquaSmart).

1. Set “DHWP OFF” (default, see programming section for instructions)
2. Set “C1 on TT” (default, see programming section for instructions)
3. Circulator-on delay will affect all zones. Circulator-off delay will have no effect.
4. Up to two 24 VAC zone valves can be powered

with the 7600B. Add an additional transformer

as shown for every two or less valves over the

original two.

5. Ensure there are no jumpers between the

terminals of the zone valves.

SK1003

3

EXPANSION

TANK

HEATING

ZONE

1

AIR

VENT

HEATING

ZONE

2

HEATING

ZONE

3*

Z

Z

Z

ZONE 1

24 VAC

ZONE

VALVE

ZONE 2

24 VAC

ZONE

VALVE

ZONE 3*

24 VAC

ZONE

VALVE

AIR

SEPARATOR

GENERAL

CIRCULATOR

COLD

WATER

INLET

TR

TW

24 VAC GAS

IGNITION SYSTEM

T
Z

TV

SK10021

L2 L1 C1 C2 ZC ZR B1 B2

NEUTRAL

HOT

120 VAC

BLACK

WHITE

CIRCULATOR

120 VAC

GENERAL

CIRCULATOR

Y

TR

TH

R

R

Y

40 VA

TRANSFORMER

ZONE 1

LOW VOLTAGE

THERMOSTAT

ZONE 1

24 VAC

ZONE VALVE

ZONE 2

LOW VOLTAGE

THERMOSTAT

ZONE 3*

LOW VOLTAGE

THERMOSTAT

Taco

550

ZONE 2

24 VAC

ZONE VALVE

ZONE 3*

24 VAC

ZONE VALVE

Honeywell

V8043E, V8044E

Honeywell

V8043F

MTR

MTR

TH/

TR

3

2

1

MTR

FIELD/MFR.

SUPPLIED

SERVICE

SWITCH

CONTINUED ON NEXT PAGE ►

* Additional zones can be added by duplicating the

plumbing and wiring of zone 3, adding additional

transformers as needed.