Tis system faults, System off, No data received – BendixKing KMD 540 - Addendum System KMD 850 User Manual

Page 30: Transponder is not reporting altitude

Advertising
background image

22

Rev 3 Jun/2004

KMD 550/850 Traffic Addendum

TIS SYSTEM FAULTS

SYSTEM OFF

If the TIS system is set to the
OFF position, Figure 29 will
be displayed.

NO DATA RECEIVED

If the KMD 550/850 is not
receiving data from the TIS
receiver then Figure 30 will
be displayed. This could indi-
cate that power is not being
provided to the TIS receiver
(e.g. a pulled breaker), the
TIS receiver is turned off, a
bad wiring connection
between the display and the
receiver, or a failed TIS
receiver.

TRANSPONDER IS
NOT REPORTING
ALTITUDE

If the transponder’s altitude
source has failed or the
transponder is put into a non-
altitude reporting mode,
Figure 31 will be displayed.

Figure 30

Figure 31

Figure 29

KMD 550-850 TRFC PG R3 7/1/04 3:24 PM Page 22

Advertising
This manual is related to the following products: