1 regulatory compliance, 1 regulatory compliance -2 – CANOGA PERKINS 2461 E1 Modem User Manual
Page 72
EdgeAccess Universal Chassis System
2461 Modem User Manual
9-2
Alarm Contact Output
Connector
6 Position Terminal Block
Rating
1.0A @ 42VAC or 700mA @ 60VDC
Performance
Composite Error Rate < 10
-10
Optical Interfaces
(850nm, LED), ST connector
(1310nm/1550nm Laser), ST, FC/PC , SC connectors
Management
Local Terminal (VT100)
GUI through the chassis DMM only
SNMP option for stand alone
Test Functions
Local Loopback, Remote Loopback,
Remote Loopback with BERT, Bi-directional
Loopback, Continuous Self Test
Loss Budgets
(Guaranteed Loss Budgets. Typical loss budgets are
2dB
greater)
1550nm Laser SMF
26dB
1310nm Laser HP, SMF/MMF
26dB
1310nm Laser SMF/MMF
17dB
850nm LED on MMF
16dB
9.1 Regulatory Compliance
•
ETL, cETL (UL 60950/CSA C22.2 No. 60950)
•
EN 60950, EN 60825-1
•
FCC Part 15B, Class A
•
EN 55022, EN 55024
•
EN 61000-3-2, EN 61000-3-3
•
C-Tick (AS/NZS 3548)
•
NEBS Level 3 Tested and Certified
•
CE Mark