Figure 15. remote configuration menu -8 – CANOGA PERKINS L357 Gigabit Ethernet Service Unit User Manual

Page 28

Advertising
background image

EdgeAccess Universal Chassis System

Table 5. Functional Configuration Option Definitions

Menu Item

Description

1) Configuration
Option Control

Software: set the L357 to follow settings in software and ignore hardware
switches
Hardware: set the L357 to follow hardware switches

2) User Port
Setting AND
3) Ext Port Setting

Set the User and Ext Ports to specific data rate, 10M, 100M, or 1000M; and
duplex, half or full, options; to automatic rate and duplexing; or disable a port

4) RMTF/LLE

Set to User LLE or Disable

5) Link Loss Fwd

Set to User to Extension, Extension to User, Both directions, or Disable LLF

6) Remote
Configuration

If the remote device is a 9145 or N525, this option appears; it opens the Remote
Configuration menu that allows you to set up selected parameters on the remote
device; see Figures 15 through 19

REMOTE CONFIGURATION
1) Functional Configuration
2) VLAN Configuration
3) VLAN ID Translation Table
4) P-Bit Translation Table
5) Local Configuration

Figure 15. Remote Configuration Menu

REMOTE FUNCTIONAL CONFIGURATION

User Port Speed/Duplex 100M/Full
Ext Port Speed/Duplex 1000M/Full

1) User Port Setting 100M/Full
2) Ext Port Setting 1000M/Full
3) 1000Base-T Master/Slave User Master/Ext Slave
4) RMTF Disabled
5) Link Loss Fwd Both Directions
6) Flow Control Disabled
7) PVST+BPDU Filtering Disabled
8) Sideband Management Enabled

Figure 16. Remote Functional Configuration Screen