9 alarm output configuration – CANOGA PERKINS 2340 Universal Fiber Optic Modem User Manual

Page 34

Advertising
background image

Model 2340 Model User Manual

4-10

4.9

Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 14 and Table 15.

To configure alarms, follow these steps:

1. From the System Configuration menu type 4, "Alarm Output Configuration," and press <Enter>.

The Alarm Output Configuration screen appears.

2. Type the number for the alarm you want to set and press <Enter>.

3. Press <Space> to cycle to Major, Minor, or Off, and press <Enter>.

4. To return to the System Configuration menu, press <Esc>.

-------------------ALARM OUTPUT CONFIGURATION----------------------------


1) Factory Defaults

2) LOS/CLS Alarm Off
3) SQL Alarm Off
4) Configuration Alarm Off
5) Power/Fan Alarm Minor
6) Power-On Self Test Alarm Major
7) BERT Alarm Minor

Figure 14. Alarm Output Configuration Screen

Table 15. Alarm Output Definitions

Alarm Description

1) Factory Defaults

Reset all alarms to factory defaults, for values, see Figure 14

2) LOS/CLS

Loss of Signal (electrical)/Composite Loss of Signal (optical); one or
both received signals fail; default is Off

3) SQL

Squelch (for received signal); default is Off

4) Configuration

Setup errors, including mismatches with other modems; default is Off

5) Power/Fan

Power is low or fan is off; default is Minor

6) Power-On Self Test Modem failed when power was turned on; default is Major

7) BERT

Bit Error Rate Test (BERT) detects data errors; default is Off