Canoga Perkins Corp. EdgeAccess Ethernet Media Converter 30-Nov-2005
Model L357-1564 V02.00 F19 Standalone

09:31:28

----------------------------------FUNCTIONAL CONFIGURATION----------------------

Local

Remote

Chassis/Slot

Standalone

Offline

User Port Speed/Duplex

Link Down

Switch Settings:
User Port Speed/Duplex Autonegotiate
Side Band Mgmt

Disabled

LLF Extension to User Disabled
LLF User to Extension

Disabled


1) Configuration Option Control Software
2) User Port Setting

100M/Full

3) Ext Port Setting

1000M/Full

4) RMTF

Disabled

5) Link Loss Echo

Disabled

6) Link Loss Fwd

Disabled



Select [1-6]:
------------------------------------Messages------------------------------------
Alarm Outputs: None

Figure 11. Functional Configuration screen

Step 7: Cable Connection

Once the changes are made to the modules, the UTP (Unshielded Twisted Pair) or fiber optic
cables can be installed. Remember that the USR port is the port connected to your local/client
device and the EXT port is the port facing the network/trunk. Connect the fiber to the EXT port.

Figure 12. Fiber optic and UTP cable connection

Step 8: IP Address/Subnet Mask/Default Gateway Set-up

From the System Configuration menu, type “5” then “enter” to access the IP/VLAN
Configuration screen. To configure the IP address, select “5,” press “enter,” and type the IP
address you wish to assign to the unit. Press enter to accept the changes. The Subnet Mask and
Default Gateway must be entered at this point as well.