Response:
<LF>^^^^^^^^U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---over capacity

<LF>_ _ _ _ _ _ _ _ U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---under capacity

<LF> - - - - - - - - U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---zero-point error

Note:

U

1

U

2

U

3

is 1or 3 bytes according to current unit: kgf, lbf, N

<LF><P>W

1

W

2

W

3

W

4

W

5

<DP>W

6

U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---normal data

Note: The decimal point position is determined by CONFIG-PRIM.D

25.6.1.2 Command: S<CR> (53h 0dh) , request current status

Response: <LF> H

1

H

2

H

3

H

4

<CR><ETX>

25.6.1.3 Command: Z<CR> (5ah 0dh)

Response: Zero function is activated (simulate ZERO key) and it returns to current indicator status.
<LF> H

1

H

2

H

3

H

4

<CR><ETX>

If ZERO function cannot be activated, it will return to current indicator status.

25.6.1.4 Command: U<CR> (55h 0dh)

Response: Changes units of measure (simulate UNIT key) and return indicator status with new units,
The new measure unit should be allowed to use
<LF> U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>

25.6.1.5 Command: L<CR> (4ch 0dh)

Response: Select next load cell to work (simulate CELL key), and returns indicator status.
<LF> H

1

H

2

H

3

H

4

<CR><ETX>

25.6.1.6 Command: X<CR> (58h 0dh)

Response: power off the indicator, just like press down the ON/OFF key to turn off the indicator.

25.6.1.7 Command: all others

Response: Unrecognized command <LF>? <CR><ETX>

25.6.2 Summary of Command and Response:

Command

Response

ASCII HEX

W<CR> 57 0d

Read scale weight:

<LF>^^^^^^^^U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---over capacity

<LF>________U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---under capacity

<LF>-------- U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>---zero-point error

<LF><p>W

1

W

2

W

3

W

4

W

5

<dp>W

6

U

1

U

2

U

3

<CR><LF>H

1

H

2

H

3

H

4

<CR><ETX>---norm

al data

S<CR> 53

0d

<LF>

H

1

H

2

H

3

H

4

<CR><ETX>; read indicator status

Z<CR> 5a

0d

<LF>

H

1

H

2

H

3

H

4

<CR><ETX> ; simulate ZERO key

U<CR> 55

0d

<LF>

U

1

U

2

U

3

<CR><LF> H

1

H

2

H

3

H

4

<CR><ETX>; simulate UNIT key

L<CR>

4c 0d <LF> H

1

H

2

H

3

H

4

<CR><ETX>; simulate SELECT key