Serial Data Output
The EFIS-D10 outputs text data through its serial port constantly during normal operation. This data is useful for a
variety of applications. All numbers are in decimal and are standard ASCII. To view the data using a terminal program,
the following settings should be used:
Baud rate:
115200
Data:
8
bit
Parity:
none
Stop:
1
bit
Flow control:
none
The format for the data being sent out the RS232 port is:
Char
Width
Description
Notes
1
2
Hour
00 to 23, current hour according to EFIS-D10A’s internal clock
3
2
Minute
00 to 59, current minute according to EFIS-D10A’s internal clock
5
2
Second
00 to 59, current second according to EFIS-D10A’s internal clock
7
2
Fractions
00 to 63, counter for 1/64 second. Data output frequency.
9
1
Pitch Sign
‘+’ or ‘-’ (positive means plane is pitched up)
10
3
Pitch
000 to 900, pitch up or down from level flight in 1/10 degrees (900 =
90
o
)