Glossary – Dynon Avionics EFIS-D10 Users Guide User Manual
Page 32

5/25/2005
28
Char
Width
Description
Notes
38
2
Vertical G’s
00 to 99, vertical G’s in units of 1/10 G (99 = 9.9 G’s)
40 2
Angle
of
Attack
00 to 99, percentage of stall angle.
42 6
Status
Bitmask
An internal-use status bitmask containing 24 bits
48
2
Product ID
Ascii-hex Dynon product ID: 01=EFIS-D10A, 10=EFIS-D10,
03=EMS-D10
50
2
Checksum
The ascii-hex 2 byte sum of all 49 preceding bytes
52
2
CR/LF
Carriage Return, Linefeed = 0x13, 0x10
As an example, the following is what one line of serial data looks like:
00082119+058-00541301200+9141+011-01+1500
3EA0C701A4
<CR><LF>
This serial data can be logged using any standard serial terminal program such as Hyper Terminal. It can then be parsed
into its respective columns by many spreadsheet programs including Microsoft Excel.