Appendix, Display notices, Technical specifications – Leica Geosystems Leica DISTO A2 User Manual

Page 7

Advertising
background image

4

Appendix

Leica DISTO™ A2 1.1.0 gb

d

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

Appendix

Display Notices

All display notices are indicated by "InFo" or "Error".
The following errors can be corrected.

Technical Specifications

* in favourable conditions (optimal target surface, room
temperature) up to 12 m. In unfavourable conditions, such as
intensive sunshine, very weakly reflecting target surface or
large temperature fluctuations, measuring accuracy may
deteriorate to approx. ± 0.25 mm/m for distances above
12 m.

InFo

Cause

Correction

252

Temperature too
high

Let device cool down.

253

Temperature too low Warm device up

255

Received signal too
weak, time for a
measurement too
long.

Use a target plate

256

Received signal too
strong

Use a target plate
(gray side)

257

Faulty measurement,
too much back-
ground light

Use a target plate
(brown side)

Error

Cause

Correction

Hardware error

If this message
remains displayed
after switching the
device off and on
several times, please
contact our dealer-
ship.

Range (for extended
distances, use a target
plate)

0,05 m to 60 m

(0.2 ft to 197 ft)

Measuring accuracy (2

σ)

typically: ± 1.5 mm

(0.06 inch)*

Smallest unit displayed

1 mm

Laser class

II

Laser type

635 nm, < 1 mW

Automatic
power off

after 180 s

Display illumination

9

Continuous measure-
ment

9

Addition / subtraction

9

Battery life,
9 V compound battery

up to 5000 measurements

Dimensions and weight

124x54x35 mm, 155 g

Temperature range:
Storage

Operation

-25°C to +70°C

(-13°F to +158°F)

-0°C to+40°C

(+32°F to + 104°F)

Advertising