Appendix

Leica DISTO™ D2 762960 en

EN

F

E

P

Switching off the beep

Press and hold simultaneously for 5

seconds:

The beep is switched off.
To reactivate it, press and hold for 5 seconds.

Appendix

Display Notices

All display notices are either displayed with

or

"Error". The following errors can be corrected.

Technical Specifications

Cause

Correction

204

Calculation error

Repeat procedure

252

Temperature too
high

Let device cool down.

253

Temperature too
low

Warm device up

255

Received signal too
weak, time for a
measurement too
long.

Use a target plate

256

Received signal too
strong

Use target plate (gray
side)

257

Faulty measure-
ment, too much
background light

Use target plate (brown
side)

258

Outside of the range
of measurement

Select measurement
distance within the
range of measurement

Error

Cause

Correction

Error

Hardware error

Should this message
remain active after
switching the instru-
ment off and on several
times, please contact
the dealerhip.

Range

0.05 m to 60 m*

(0.16 ft to 197 ft*)

Measuring accuracy (2 σ)

typically ± 0.06 in**

Smallest unit displayed

1 mm (

1

/

16

in)

Laser class

2

Laser type

635 nm, < 1 mW

Protection against
splashes and dust

IP 54, dust-proof,

splash-proof

Autom. power off:
Laser
Instrument

after 90 s

after 180 s

Illumination

9

Folding out endpiece

9

Battery life,
Type 2 x AAA

up to

5 000 measurements

Cause

Correction