18 en message codes, Care, Warranty – Leica Geosystems Leica DISTO E7400x User Manual
Page 19: Safety instructions, Areas of responsibility
![background image](/manuals/651777/19/background.png)
Leica DISTO
TM
E7400x 788480a
18
EN
Message Codes
If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:
Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Warranty
The device comes with a 3-year warranty. To
receive the 3-year warranty, the product
must be registered on www.disto.com
within 8 weeks of the purchase date. If the
product is not registered, a 2-year warranty
applies.
Safety Instructions
The person responsible for the instrument
must ensure that all users understand these
directions and adhere to them.
Areas of responsibility
Responsibilities of the manufacturer
of the original equipment:
Leica Geosystems AG
Heinrich-Wild-Strasse
CH-9435 Heerbrugg
Internet: www.disto.com
The company above is responsible for
supplying the product, including the User
Manual in a completely safe condition.
The company above is not responsible for
third party accessories.
Responsibilities of the person in
charge of the instrument:
• To understand the safety instructions on
the product and the instructions in the
User Manual.
• To be familiar with local safety regulations
relating to accident prevention.
• Always prevent access to the product by
unauthorised personnel.
No.
Cause
Correction
156
Transverse tilt greater
than 10°
Hold the instrument
without any transverse tilt.
162
Calibration mistake
Make sure, the device is
placed on a absolutely
horizontal and flat surface.
Repeat the calibration
procedure. If the mistake
still occurs, contact your
dealer.
204
Calculation error
Perform measurement
again.
252
Temperature too high Let device cool down.
253
Temperature too low Warm device up.
255
Received signal too
weak, measuring time
too long
Change target surface
(e.g. white paper).
256
Received signal too
high
Change target surface
(e.g. white paper).
257
Too much back-
ground light
Shadow target area.
258
Measurement outside
of measuring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.