5.4. Error reports

No.

Format

Meaning

203

@E203

Prohibited parameter in command entry, or prohibited command, or non-valid
result

217

@E217

Parameter set-up incorrect (Contact Leica Geosystems)

221

@E221

Parity error (Prior to contacting Leica Geosystems please check the Terminal
settings)

222

@E222

Interface buffer overflow
(Contact Leica Geosystems if error occurs when sending less than 24
characters)

223

@E223

Interface framing error
(Contact Leica Geosystems)

224

@E224

GSI buffer overflow
(Contact Leica Geosystems if error occurs when sending less than 24
characters)

252

@E252

Temperature too high
(contact Leica Geosystems if error occurs at room temperature)

253

@E253

Temperature too low
(contact Leica Geosystems if error occurs at room temperature)

255

@E255

Received signal too weak, distance < 250mm
(Use different target and distances, if the problem persists, please contact Leica
Geosystems)

256

@E256

Received signal too strong
(Use different target and distances, if the problem persists, please contact Leica
Geosystems)

257

@E257

Too much background light
(Use different target and distances, if the problem persists, please contact Leica
Geosystems)

272

to

299

@E272

Hardware failure (Contact Leica Geosystems)