Appendix, Selecting particular values in the display, Transmission of user-entered mea- surements – Leica Geosystems Leica DISTO A6 - User Manual User Manual

Page 12: Message codes

Advertising
background image

9

Appendix

Leica DISTO™ A6 1.1.0 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

RC

ROK

PL

H

RUS

CZ

repeat the measurement and then transmit it.

Selecting particular values in the
display

By using the Min. / Max. function particular measure-
ments can be selected for transmission. The display
shows a number of measurements (min., max., last
measurement taken). You can select a particular
measurement by using a longer press on the PLUS -
key {A, 3} or a longer press on the MINUS - key
{A, 13}. When selected the measurement blinks.
Once selected and blinking, the measurement can be
transmitted using the BLUETOOTH

®

- key {A, 14}.

The same selection process can be used for areas,
volumes, indirect measurements and room dimen-
sions.

Transmission of user-entered mea-
surements

A measurement on the display can be changed if you
wish. By pressing the EQUAL - key {A, 5} the value
blinks and can then be changed using the PLUS - key
{A, 3} and the MINUS - key {A, 13}. Pressing the keys
for longer increases the rate of change. Pressing the
EQUAL - key {A, 5} again confirms the change and
the value can be transmitted as normal.

)

NOTE

The free software supplied is designed to

provide the user with basic functionality. Leica
Geosystems provides no warranty for this free soft-

ware and offers no support for it. Leica Geosystems
accepts no liability whatsoever arising from the use
of the free software and is not obliged to provide
corrections nor to develop updates or upgrades.

You can find numerous commercial vendors of soft-
ware for a wide range of applications on our home-
page.

Appendix

Message Codes

All message codes will be displayed with either "InFo"
or "Error".
The following mistakes can be corrected:

InFo

Cause

Remedy

204

Calculation error

Repeat procedure

206

No endpiece detec-
tion

Attach the endpiece
properly. If error still
occurs, replace the
endpiece.

240

Error in data trans-
mission

Repeat process

245

2nd key pressed
although no BLUE-
TOOTH

®

connection

exists.

Establish BLUE-
TOOTH

®

connection

252

Temperature too
high

Cool down instrument

253

Temperatur too low Warm up instrument

Advertising