Cypress CY7C1305BV25 User Manual

Page 12

Advertising
background image

CY7C1307BV25

CY7C1305BV25

Document #: 38-05630 Rev. *A

Page 12 of 21

TAP Controller Block Diagram

TAP Electrical Characteristics

Over the Operating Range

[12, 15, 17]

Parameter

Description

Test Conditions

Min.

Max.

Unit

V

OH1

Output HIGH Voltage

I

OH

=

−2.0 mA

1.7

V

V

OH2

Output HIGH Voltage

I

OH

=

−100 µA

2.1

V

V

OL1

Output LOW Voltage

I

OL

= 2.0 mA

0.7

V

V

OL2

Output LOW Voltage

I

OL

= 100

µA

0.2

V

V

IH

Input HIGH Voltage

1.7

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

–0.3

0.7

V

I

X

Input and Output Load Current

GND

≤ V

I

≤ V

DDQ

−5

5

µA

TAP AC Switching Characteristics

Over the Operating Range

[13, 14]

Parameter

Description

Min.

Max.

Unit

t

TCYC

TCK Clock Cycle Time

50

ns

t

TF

TCK Clock Frequency

20

MHz

t

TH

TCK Clock HIGH

20

ns

t

TL

TCK Clock LOW

20

ns

Set-up Times

t

TMSS

TMS Set-up to TCK Clock Rise

10

ns

t

TDIS

TDI Set-up to TCK Clock Rise

10

ns

t

CS

Capture Set-up to TCK Rise

10

ns

Hold Times

t

TMSH

TMS Hold after TCK Clock Rise

10

ns

t

TDIH

TDI Hold after Clock Rise

10

ns

t

CH

Capture Hold after Clock Rise

10

ns

Notes:

12. These characteristic pertain to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in the Electrical Characteristics Table.
13. Parameters t

CS

and t

CH

refer to the set-up and hold time requirements of latching data from the boundary scan register.

14. Test conditions are specified using the load in TAP AC test conditions. t

R

/t

F

= 1 ns.

0

0

1

2

.

.

29

30

31

Boundary Scan Register

Identification Register

0

1

2

.

.

.

.

106

0

1

2

Instruction Register

Bypass Register

Selection
Circuitry

Selection
Circuitry

TAP Controller

TDI

TDO

TCK

TMS

[+] Feedback

Advertising
This manual is related to the following products: