24 volt system with low-btu standing pilot, 24 volt system with intermittent ignition (i.i.d.) – Louisville Tin and Stove DVCF408B-R User Manual

Page 2

Advertising
background image

CONTENTS

Introduction………………………………. 2
Specifications and Dimensions……………

2

Safety Rules………………………………. 3
Clearances………………………………… 4, 5
Location…………………………………… 6
Installation…………………………………

6

Operation………………………………….

7

Lighting Instructions………………………

8, 9

Pilot Adjustment…………………………..

10

Removing Burner……………………….

10

Proper Burner Flame……………………

10

Optional Side Discharge Kit……………

14

Terminal Block Wiring…………………

13

Manual Reset……………………………

13

Maintenance Instructions……………….

13

Trouble Shooting……………………….. 16,17
Parts Drawing…………………………...

18

Parts List………………………………... 19,20
Warranty…………………………………

22

INTRODUCTION

Read these installation and operating instructions carefully before you install or attempt to use this Direct
Vent Counterflow Wall Furnace. If you do not understand any part of the instructions, consult local authorities,
a qualified installer, service agency or the gas supplier. FAILURE TO READ OR UNDERSTAND THESE
INSTRUCTIONS CAN RESULT IN MALFUNCTION, INEFFICIENT OPERATION, PROPERTY
DAMAGE, SERIOUS INJURY OR DEATH
.

SPECIFICATIONS AND DIMENSIONS

Your Direct Vent Counterflow Wall Furnace is shipped in two cartons. One carton contains the furnace,
thermostat, thermostat wire and insulated staples. The second carton will have the vent tube, air intake tube
and vent cap assembly. After the furnace has been removed from the carton check the rating plate to verify
that the model number is correct and that the wall furnace is equipped with the type gas you intend to use.

The appliance may be installed in an aftermarket permanently located, manufactured (mobile)
home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a
certified kit is used.

Model

Type

Type

Btu/Hr. Gas

Blower

Approx.

Number

Control Gas

Input

Inlet

Finished Dimensions

Speed

Amps

CFM Ship. Wt.

24 VOLT SYSTEM WITH LOW-BTU STANDING PILOT

DVCF403B-R

24 Volt

Nat.

40,000

½”

14-5/16”Wx78-5/8”Hx11-3/4”D

1

1.95

320

128 Lbs.

DVCF404B-R

24 Volt

L.P.

40,000

½”

14-5/16”Wx78-5/8”Hx11-3/4”D

1

1.95

320

128 Lbs.

DVCF653B-R

24 Volt

Nat.

62,500

½”

14-5/16”Wx87-5/16”Hx11-3/4”D

2

3.05

440

142 Lbs.

DVCF654B-R

24 Volt

L.P.

62,500

½”

14-5/16”Wx87-5/16”Hx11-3/4”D

2

3.05

440

142 Lbs.

24 VOLT SYSTEM WITH INTERMITTENT IGNITION (I.I.D.)

DVCF407B-R

24 Volt

Nat.

40,000

½”

14-5/16”Wx78-5/8”Hx11-3/4”D

1

2.2

320

130 Lbs.

DVCF408B-R

24 Volt

L.P.

40,000

½”

14-5/16”Wx78-5/8”Hx11-3/4”D

1

2.25

320

130 Lbs.

DVCF557B-R

24 Volt

Nat.

55,000

½”

14-5/16”Wx87-5/16”Hx11-3/4”D

2

3.3

440

144 Lbs.

DVCF558B-R

24 Volt

L.P.

55,000

½”

14-5/16”Wx87-5/16”Hx11-3/4”D

2

3.35

440

144 Lbs.