Alternate Switch Location

The remote switch can be installed on either side of
the access door. Mount the switch to the switch bracket
provided. Screw the bracket on either side of the frame,
line up the screws with the prepunched holes. (Fig. 8)

FP1024

alternate

remote switch

location

1/27/00 djt

FP1024

Fig. 8 Alternate switch location.

EB-1 Electrical Box

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.
For USA installations, follow the local
codes and the national Electrical Code
ANSI/NFPA No. 70.
It is strongly suggested that the wiring of
the EB-1 Electrical Junction Box be carried
out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.
The EB-1 electrical junction box has been

supplied standard on the DV360/580 models to allow
for the easy installation of an optional fan kit.
To connect the EB-1 box to the house electrical supply,
follow the steps below.
1. Unscrew the retaining screw from the EB-1 base

plate (Fig. 9) and remove the EB-1 assembly from
the fireplace.

2. Remove the front cover of the EB-1 box.
3. Remove the plug socket assembly from the EB-1

box.

4. Feed the supply line in from the outside through the

cable clamp. (Fig. 9)

5. Connect black wire of the power supply line to the

brass screw (polarized) of the socket assembly.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97

OUTSIDE

Electrical Box

FRONT OF UNIT

INSIDE

FRONT

OF UNIT

FP580

Fig. 9 EB-1 receptacle.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable
with the clamp on the outside of the unit to prevent
strain on the connections.

9. The EB-1 electrical junction box is now ready to sup-

ply power to the FK12 or FK24 fan kits if fitted.