Tap controller block diagram, Tap electrical characteristics – Cypress CY7C1143V18 User Manual

Page 16

Advertising
background image

CY7C1141V18, CY7C1156V18
CY7C1143V18, CY7C1145V18

Document Number: 001-06583 Rev. *D

Page 16 of 28

TAP Controller Block Diagram

Figure 3. Tap Controller Block Diagram

TAP Electrical Characteristics

The Tap Electrical Characteristics table over the operating range follows.

[12, 13, 14]

Parameter

Description

Test Conditions

Min

Max

Unit

V

OH1

Output HIGH Voltage

I

OH

=

−2.0 mA

1.4

V

V

OH2

Output HIGH Voltage

I

OH

=

−100 μA

1.6

V

V

OL1

Output LOW Voltage

I

OL

= 2.0 mA

0.4

V

V

OL2

Output LOW Voltage

I

OL

= 100

μA

0.2

V

V

IH

Input HIGH Voltage

0.65 V

DD

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

–0.3

0.35 V

DD

V

I

X

Input and Output Load Current

GND

≤ V

I

≤ V

DD

–5

5

μA

0

0

1

2

.

.

29

30

31

Boundary Scan Register

Identification Register

0

1

2

.

.

.

.

106

0

1

2

Instruction Register

Bypass Register

Selection
Circuitry

Selection
Circuitry

TAP Controller

TDI

TDO

TCK

TMS

Notes

12. These characteristic pertain to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in the Electrical Characteristics table.
13. Overshoot: V

IH

(AC) < V

DDQ

+ 0.35V (Pulse width less than t

CYC

/2), Undershoot: V

IL

(AC) >

0.3V (Pulse width less than t

CYC

/2).

14. All voltage refer to ground.

[+] Feedback

[+] Feedback

Advertising
This manual is related to the following products: